2FT
1-6-10
6. Remove the springs, stop ring and bushing
and then the shaft holder from the upper
paper feed unit.
Figure 1-6-15
7. Remove the drawer forwarding pulley from
the upper paper feed unit.
8. Remove the drawer paper feed pulley from
the upper paper feed unit.
9. Replace the drawer forwarding pulley and
drawer paper feed pulley and refit all the
removed parts.
Figure 1-6-16
Upper paper feed unit
Bushing
Stop ring
Shaft holder
Spring
Spring
Drawer forwarding pulley
Drawer paper feed pulley