2FT
1-3-34
14. Connect the pulled out connector of the job
separator to the LED PCB of the left front
cover JS and then pass the wire through the
two positions of the groove of the left front
cover JS.
Figure 1-3-63
15. Fit the pawl of the left front cover JS into the
hole of the left front cover to attach the left
front cover JS.
* In this time, take care that the routed wire
in the groove does not come off.
16. Attach the inner cover that has been
removed by Procedure 2 to its original posi-
tion.
17. Close the front cover.
Figure 1-3-64
Operation check
1. Insert the power plug of the MFP into an out-
let and then turn the power switch on.
2. Set the "copy ejection location" of the
machine default settings to job separator.
3. Make a test copy to check that a copy is
ejected to the job separator tray.
Grooves
Left front cover JS
LED PCB
Connector
Holes
Left front cover JS