2FT
1-5-35
(5)
The scanner motor
does not operate.
Broken scanner motor coil.
Check for continuity across the coil. If none, replace the scanner
motor.
Poor contact in the scanner
motor connector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
(6)
Cooling fan motor 1
does not operate.
Broken cooling fan motor 1
coil.
Check for continuity across the coil. If none, replace cooling fan
motor 1.
Poor contact in the cooling
fan motor 1 connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
(7)
Cooling fan motor 2
does not operate.
Broken cooling fan motor 2
coil.
Check for continuity across the coil. If none, replace cooling fan
motor 2.
Poor contact in the cooling
fan motor 2 connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
(8)
Cooling fan motor 3
does not operate.
Broken cooling fan motor 3
coil.
Check for continuity across the coil. If none, replace cooling fan
motor 3.
Poor contact in the cooling
fan motor 3 connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
(9)
Cooling fan motor 4
does not operate.
Broken cooling fan motor 4
coil.
Check for continuity across the coil. If none, replace cooling fan
motor 4.
Poor contact in the cooling
fan motor 4 connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
(10)
Toner motor does not
operate.
Broken toner motor coil.
Check for continuity across the coil. If none, replace toner motor.
Poor contact in the toner
motor connector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
(11)
The drawer drive
motor does not oper-
ate.
Poor contact in the drawer
drive motor connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Broken drawer drive motor
gear.
Check visually and replace the drawer drive motor if necessary.
Defective drawer drive
motor.
Run maintenance item U030 and check if the drawer drive motor
operates when YC9-2,3,4,5 on the drawer main PCB goes low. If
not, replace the drawer drive motor.
Defective drawer main
PCB.
Run maintenance item U030 and check if YC9-2,3,4,5 on the
drawer main PCB goes low. If not, replace the drawer main PCB.
(12)
The paper feed
clutch does not oper-
ate.
Broken paper feed clutch-
coil.
Check for continuity across the coil. If none, replace the paper
feed clutch.
Poor contact in the paper
feed clutch connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective engine PCB.
Run maintenance item U032 and check if YC8-3 on the engine
PCB goes low. If not, replace the engine PCB.
Problem
Causes
Check procedures/corrective measures
Содержание KM-2550
Страница 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Страница 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Страница 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Страница 282: ......