2FT-1
1-4-38
U251
Checking/clearing the maintenance count
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count. Also to clear the count during maintenance service.
Method
Press the start key. The maintenance count is displayed.
Clearing
1. Select the CLEAR using the up/down cursor keys.
2. Press the start key. The count is cleared, and the screen for selecting a maintenance item No. is dis-
played.
Setting
1. Select the COUNT using the up/down cursor keys.
2. Enter a seven-digit count using the numeric keys.
3. Press the start key. The count is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
U252
Setting the destination
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after replacing the backup RAM on the main PCB or initializing the backup RAM by running
maintenance item U020, in order to return the setting to the value before replacement or initialization.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the destination using the up/down cursor keys. The selected item is displayed in reverse.
2. Press the start key. The setting is set, and the machine automatically returns to the same status as
when the power is turned on.
Completion
To exit this maintenance item without changing the current count, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
Supplement
The specified initial settings are provided according to the destinations in the maintenance items below. To
change the initial settings in those items, be sure to run maintenance item U021 after changing the destina-
tion.
Initial setting according to the destinations
Maintenance
item No.
Description
Display
Description
JAPAN METRIC
Metric (Japan) specifications
INCH
Inch (North America) specifications
EUROPE METRIC
Metric (Europe) specifications
ASIA PACIFIC
Metric (Asia Pacific) specifications
CHINA
China specifications
Maintenance
item No.
Title
Japan
Inch
Europe Metric,
Asia Pacific, China
253
Switching between double and single
counts
Single
Double
Double
Содержание KM-2550
Страница 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Страница 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Страница 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Страница 282: ......