2FT-1
1-5-18
(2) Self diagnostic codes
Code
Contents
Remarks
Causes
Check procedures/corrective measures
C0030
Fax control PCB* system problem
Processing with the fax software was
disabled due to a hardware or software
problem.
Defective fax con-
trol PCB.
Replace the fax control PCB and check for
correct operation.
C0070
Fax control PCB* incompatibility
detection problem
Fax software is not compatible with main
software.
Fax software or
main software is
something of the
other machine.
Check the version of the Fax software and
the main software, upgrade the version to
the compatible software.
C0100
Backup memory read/write problem
(main PCB flash)
Read and write data does not match.
Defective main
PCB.
Replace the main PCB and check for correct
operation.
C0110
Backup memory data problem (main
PCB flash)
Data in the specified area of the backup
memory does not match the specified
values.
Problem with the
backup memory
data.
Turn safety switch off and back on and run
maintenance item U020 to set the contents
of the backup memory data again.
Defective backup
RAM.
If the C0110 is displayed after re-setting the
backup memory contents, replace the main
PCB.
C0120
Drum EEPROM read/write problem
Read and write data does not match.
Defective drum
EEPROM or main
PCB.
Replace the main PCB and check for correct
operation.
C0130
Backup memory read/write problem
(main PCB EEPROM)
Read and write data does not match.
Defective
EEPROM or main
PCB.
Replace the main PCB and check for correct
operation.
C0140
Backup memory data problem (main
PCB EEPROM)
Data in the specified area of the backup
memory does not match the specified
values.
Problem with the
backup memory
data.
Turn safety switch off and back on and run
maintenance item U020 to set the contents
of the backup memory data again.
Defective
EEPROM.
If the C0140 is displayed after re-setting the
backup memory contents, replace the
EEPROM or main PCB.
C0150
Backup memory read/write problem
(engine PCB)
Read and write data does not match.
Defective engine
PCB.
Replace the engine PCB and check for cor-
rect operation.
C0160
Backup memory data problem (engine
PCB)
Data in the specified area of the backup
memory does not match the specified
values.
Problem with the
backup memory
data.
Turn safety switch off and back on and run
maintenance item U020 to set the contents
of the backup memory data again.
Defective backup
RAM.
If the C0160 is displayed after re-setting the
backup memory contents, replace the
engine PCB.
C0170
Accounting count problem
When the power is turned on, the total
count and the scan count are abnormal
both on the main PCB and the engine
PCB.
Defective main
PCB or engine
PCB.
Replace the main PCB or engine PCB and
check for correct operation.
*: Optional.
Содержание KM-2550
Страница 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Страница 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Страница 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Страница 282: ......