2FT
2-1-14
Timing chart 2-1-3 Transfer and separation sections operation
a: The drive motor (DM) turns on at the same time, the transfer bias (+590 V) turns on.
b: 230 ms after secondary paper feed starts, the transfer bias turns off.
c: 40 ms after the transfer bias turns off, separation charging starts.
d: 10 ms after separation charging starts, the transfer bias (-40
µ
A) turns on.
e: 290 ms after the registration switch (RSW) turns off, the transfer bias (-20
µ
A) turns on. And 50 ms after the transfer
bias turns off.
f: 40 ms after the transfer bias turns off, separation charging ends.
g: 260 ms after separation charging ends, the transfer bias (+590 V) turns on.
h: The drive motor (DM) turns off at the same time, the transfer bias turns off.
DM
PFCL
RSW
RM
Dev.BIAS
Primary feed
Scondary feed
Primary feed
Scondary feed
Transfer
BIAS
Separation
charging
ESW
200 ms
340 ms
155 ms
40 ms
40 ms
40 ms
155 ms
10 ms
230 ms
220 ms
120 ms
85 ms
230 ms
40 ms
1585 ms
290 ms
260 ms
50 ms
260 ms
10 ms
85 ms