This document is the property of KYMATI GmbH and must not be copied or disclosed without its written authorisation.
- KYMATI GmbH – 2021
KY.MAN.0164 (2.0)
KY-RAY 3D.03.01 User Manual
Doc.- No.: KY.MAN.0164
Version:
2.0
Date:
16.06.2021
Page:
26 of 36
Open connector sockets need to be protected with a cap. Only with sealed
connectors, the device has its stated IP rating
6.2
Powering Up
First connect all cables to the devices and then power up them.
After the installation of the devices the power can be turned on. Therefore, a proper power
supply as described in chapter 4.4 must be used.
After power up, the power LED shall illuminate constantly, stating that the device is properly
powered. In case of wrong polarity, the device has a polarity protection, hence if the power
LED is not illuminating, the power must be removed immediately.
6.3
Initial Configuration
All devices are shipped with a preconfigured IP address 192.168.75.100.
Before configuring the device using the provide KYMATI Primary Radar Quickstart software,
please make sure that your network device is configured as 192.168.75.1 with netmask
255.255.255.0. On Windows systems the network configuration should be similar to the ones
below:
Figure 17: Network Configuration