5
System Installation
5.1
Wiring Diagram
To power the device, there are three options:
1.) An external DC power supply via the connector X1 can be used
2.) A PoE (802.11af) can be provided via X2
3.) or both interfaces can be used to power the device to have a redundant power supply.
For data communication there are two interfaces. A RS-485 interface on connector X1 and an
Ethernet interface on connector X2 (see Figure 11). The current revision of the product only
supports Ethernet.
Only one data interface should be used at a time.
If other interfaces/protocols like Profinet, Profibus, Ethernet/IP, ModBus, digital I/Os or similar
are needed, an accessory from the KY-XTRA B family is necessary (for more details please
visit
www.kymati.com
).