Страница 3: ...es installation and commissioning network management etc to provide users with references in startup expansion and routine maintenance It is a practical teaching material that can be used by users in...

Страница 4: ...s of KIEN6000 industrial Ethernet switch Appendix C introduces abbreviations used in this manful Statement as product and technology upgrades and improves constantly the contents of this document may...

Страница 5: ...other equipments should be firmly interconnected and frequently checked In the following cases please immediately disconnect the power supply and contact with our company 1 Water gets into the equipme...

Страница 6: ...sers during operation The implications of these signs are as follows Warning pay special attention to the notes behind the mark improper operation will result in serious damage of the switch or injury...

Страница 7: ...m structure 10 3 2 Switch Structure 10 3 2 1 Case 10 3 2 2 Front panel 12 3 2 3 Top panel 15 3 2 4 Bottom panel 19 Chapter 4 Hardware Mounting 21 4 1 Mounting requirements 21 4 2 Main unit mounting 22...

Страница 8: ...6 Networking Mode and System Configuration 32 6 1 Networking mode 32 6 2 System configuration 35 Appendix A Twisted pair and Pin Distribution 36 Appendix B Cable Type and Specifications 39 Appendix C...

Страница 9: ...N6000 industrial Ethernet switch provides two mounting ways DIN rail and wall mounting On the front panel there are two pairs of uplink redundant 100Base FX single mode or multi mode optical fiber int...

Страница 10: ...alarm of power and ports link 5 Setting and query for port working mode prioritization and rate Industrial Power 1 Industrial power input of DC24V DC18V 36V 2 Reliable protection for EMC and against...

Страница 11: ...ng apart after opening the case If a hard object is used to unclench the case do not overly extend the hard object into the case to avoid damage of the equipments inside the case After opening the cas...

Страница 12: ...dwidth of system 5 6G Mac address list 8K Max VLAN quantity 4094 Electromagnetic compatibility interference EN55022 Electromagnetic compatibility immunity EN50082 2 Ethernet port Physical port shielde...

Страница 13: ...automatically working in full duplex or half duplex operation mode The transmission distance is 100m max 2 Two pairs of uplink redundant 100Base FX single mode or multi mode optical fiber interfaces...

Страница 14: ...is not supported at user s end and different priority is necessary for different ports services Only the data package without Prioritization in the Packet in the ports can be affected by this functio...

Страница 15: ...m based on percentage With the control percentage the broadcast flow of KIEN6000 will be monitored and controlled effectively The switch will filter out the over flow and ensure the flow percentage is...

Страница 16: ...is used for optical fiber interface offering reliabile performance 3 Industrial power supply with overcurrent overvoltage and EMC protection 4 EMC protection is provided for all TP ports and CONSOLE i...

Страница 17: ...emperature resistance of equipment Discarding the traditional form of axial fan heat dispersion reduces power consumption of the entire unit and increases the stability of the system The figuration of...

Страница 18: ...hell when the equipment is working to avoid burning 3 2 2 Front panel The front panel of KIEN6000 industrial Ethernet switch has integrated two pairs of uplink redundant optical fiber interfaces six u...

Страница 19: ...ith port number of 1 and 2 each port has self adaptation function Two uplink redundant 10Base T 100Base TX Ethernet RJ45 ports can be set as either straight through mode or redundant ring mode Straigh...

Страница 20: ...n POWER 1 is connected and operates normally POWER1 Off POWER 1 is not connected or operates abnormally On POWER 2 is connected and operates normally POWER2 Off POWER 2 is not connected or operates ab...

Страница 21: ...used simultaneously to input power to KIEN6000 from two independent sets of external DC power supply systems so that when either of the two sets of power supply systems fails the equipment can operat...

Страница 22: ...Alarming enabling message such as power failure alarming port link alarming network alarming etc can be set via network management In normal state without alarming the terminal is in open state when a...

Страница 23: ...e 9 pin serial port of the control computer Operating the local management software provided by KYLAND Telecom in the control computer allows configuration enquiry and management of the KIEN6000 equip...

Страница 24: ...et to redundant mode F is used for setting the equipment to local or remote when the optical fiber interface is in redundant mode If T is in OFF when F shifts to ON the equipment is set as local other...

Страница 25: ...fiber redundant ring network only one end equipment should be set as local and others as remote 3 2 4 Bottom panel There is a threaded hole for grounding in the bottom panel of KIEN6000 M3 8 screw and...

Страница 26: ...Kyland Telecom 20 Figure 3 8 Grounding method for KIEN6000 case...

Страница 27: ...es redundant 24VDC power supply 18VDC 36VDC 2 Environment requirement temperature 35 75 relative humidity 10 95 non condensable 3 Grounding resistance requirement 5 4 Check whether optical fiber cable...

Страница 28: ...IEN6000 2 Whether there is power inlet on DIN rail suitable for KIEN6000 operation Kyland Telecom Model S N INPUT DC18 36V 6VA KIEN6000T 2M E6T2M050068 http www kyland com cn Made In China Invisible l...

Страница 29: ...E1A8T050068 S N KIEN1000 8T DIN Rail Spri ng CAUTION The casing is part of the heat sink design and may be hot to the touch Made In China http www kyland com cn INPUT DC18 36V 6VA E1A8T050068 S N Kyla...

Страница 30: ...he two screws fastening the DIN rail connector socket on KIEN6000 equipment and remove the green DIN rail connector socket 2 Take out the wall mounting plate and the screws cross recessed countersunk...

Страница 31: ...on bolts in the holes on the wall screw down the tapping screws into the plastic expansion bolts with a cross head screwdriver but do not screw down thoroughly reserve a distance of around 5 if you se...

Страница 32: ...nection After properly mounting KIEN6000 it is ready for cable mounting and connection mainly including cable connection for the following interfaces 1 Service interface KIEN6000 provides 10Base T 100...

Страница 33: ...ser product requirements and harmless to eyes under normal operation However when the equipment is switched on do not stare directly into the optical fiber transmitting interface and the end of optica...

Страница 34: ...wiring check whether the specifications models and quantities of all cables comply with the construction drawing design and contract requirements 2 Before cable wiring it is necessary to check whether...

Страница 35: ...unding conductor should be not folded or blended together If a cable line is overly long coil and place it in the middle of the cabling rack do not let it cover on other cables 9 When laying the pigta...

Страница 36: ...es connect with the network port of the two testing computers by straight through network cable transmit Ping command mutually both sides can correctly Ping to each other and no data package is lost A...

Страница 37: ...d The IP address of testing computer 1 is 192 168 100 10 and that of the testing computer 2 is 192 168 100 11 operating command in the Operation column of the Starting menu of the operating testing co...

Страница 38: ...fiber interface an optical fiber redundant ring network can be formed The recovery time of the ring network redundancy is less than 300ms when the system is in fault It is widely applied in many fiel...

Страница 39: ...com put er Figure 6 1 Optical fiber redundant ring network composed by KIEN6000 KIEN6000 can form an optical fiber redundant double ring network as shown in Figure 6 2 When a fiber disconnection happ...

Страница 40: ...d by KIEN6000 Attention When KIEN6000 is forming a redundant ring network connection of optical port 4 and 8 are recommended namely the optical port 4 of one end equipment shall be connected with the...

Страница 41: ...with fixed configuration The fiber port can be single mode or multi mode The power supply voltage is DC 24V The specific configuration and its corresponding models are shown as Table 6 1 Table 6 1 Con...

Страница 42: ...rming to FCC standard Fig A 1 Shows how the connector of RJ 45 is numbered please make sure that the inserting direction is correct 1 8 8 1 Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 1...

Страница 43: ...X is listed in the table A 1 Table A 1 Pin distribution of 10Base T 100Base TX Pin MDI X signal name MDI signal name 1 Receiving data RD Output data TD 2 Receiving data RD Output data TD 3 Output data...

Страница 44: ...Kyland Telecom 38 Figure A 3 Cable sequence of cross over cable...

Страница 45: ...le B 1 Cable type and specifications Cable Type Max length Connector 10Base T Cat 3 4 and 5 100 ohm UTP 100m 328 foot RJ 45 100Base TX Cat 5 100 ohm UTP 100m 328 foot RJ 45 100Base FX 50 125 or 62 5 1...

Страница 46: ...iguration function Traffic Control It is a congestion control mechanism The network equipment sends the data to the equipment which has overloaded and causes the port to congest The traffic control ca...

Страница 47: ...Kyland Telecom 41...

Страница 48: ...BARCELONA MADRID C Pardo 8 bajos 08027 Barcelona Tel 34 933 408 712 Fax 34 933 401 399 www davantel com C Arturo Soria 320 28033 Madrid Tel 34 913 023 758 info davantel com...