Step 4: Calibrate the Lock Edge Probe (Option)
KVAL Operation Manual
4-14
Step 4: Calibrate the Lock Edge Probe (Option)
The
Lock Edge Drill
is an machine option that routes a lock on the door edge. This section focuses
on the
Edge Probe Calibration
. For instructions about entering calibration data,
Calibration Data” on page 4-6.
Lock Edge Probe
At the
Calibration Screen
, select
Door Stops and Probes
to display the calibration menu.
Before Probe Depth Calibration
Before calibrating the Lock Probe depth (
Z-Axis
) verify the
X-Axis
and
Y-Axis
.
This is a visual test.
Run a Door Job. Check the Depth
Probe Pad position as it touches the
door edge. Pad on probe should
cover at least 50% of the door edge.
+
X
+
Y
-
X
-
Y
Probe Pad
Содержание DL-NCD
Страница 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Страница 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Страница 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Страница 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Страница 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Страница 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Страница 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Страница 142: ......
Страница 143: ......