Step 3: Calibrate the Face Carriage
KVAL Operation Manual
4-13
Process to Calibrate the Face Carriage Head
Note:
It is recommended to use a solid core door when calibrating the
Z-Axis
. Solid
core doors lends itself to finer measurements of the depth.
For instructions about entering calibration data,
see “How to Enter Calibration Data” on page 4-6.
1.
Create a
Door Job
of a
FaceRectangle
cut of your choice with a depth of 0.25 inches.
2.
Add
Door Job
to the
Queue
.
3.
Once the cut is machined, check location of the cut. If the cut is not in the specifica-
tions, find which needs to be calibrated.
4.
Perform the Left Hand Rule at the lock side of the door to determine axis direction.
See illustration below.
• If the location is out of specification in the
length
of the door, the
X-Axis
needs to
be adjusted.
• If the location is out of specification in the
width
of the door, the
Y-Axis
needs to be
adjusted.
• If the plunge cut is out of specification, check the
Configuration Menu
.
Face Axis Direction
+
X
+
Y
+
Z
Z-Axis----Adjust update the Configuration Menu.
-
X
-
Y
-
Z
To determine axis direction.
Stand at the Lock Side of
Door, point down on the
face of the door with the left
hand rule.
Содержание DL-NCD
Страница 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Страница 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Страница 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Страница 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Страница 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Страница 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Страница 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Страница 142: ......
Страница 143: ......