5.5

Replacing the touch controls

Should you determine that the control panel circuit board is not functioning, replace it as follows: 

1.

Open the hood and remove the right-hand panel of
the edge suction device by means of operating the
respective lever.

2.

Loosen the screws that fasten the cover of the
control panel to the inner support and remove the
cover.

3.

Remove the two screws that fasten the bracket to
the casing and remove the bracket (the control panel
is attached to the bracket).

4.

Loosen the screws for releasing the control panel
unit. Open the control panel unit and remove the flat
wire.

control panel unit

Содержание KD 9550.0

Страница 1: ...Chimney cooker hood KD 9550 0...

Страница 2: ...Manual H5 60 85 02 Responsible U Laarmann K PPERSBUSCH HAUSGER TE AG E mail uwe laarmann kueppersbusch de Phone 0209 401 732 Kundendienst Fax 0209 401 743 Postfach 100132 Date 16 08 2005 45801 Gelsen...

Страница 3: ...ation display 11 4 3 Resetting the saturation display 11 5 Accessing the components 12 5 1 The individual units 12 5 2 Procedure for repairs 13 5 3 Changing the halogen lamps 14 5 4 Replacing the tran...

Страница 4: ...rent circuit breaker must always be used The earthed conductor resistance must not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functioning of...

Страница 5: ...ted and vapours will not be sufficiently removed The cooker hood has been designed to extract vapours generated during the cooking procedure The hood is supplied for extraction air operation If it is...

Страница 6: ...xhaust gas chimneys which are not in operation prior approval must be granted by the master chimney sweep responsible 4 In the case of extraction air operation of the cooker hood and the simultaneous...

Страница 7: ...al line 200mm to the right of the vertical gauge line 4 Repeat this procedure on the opposite side and check the alignment 5 Mark another reference dot 2 as described 180mm from the vertical reference...

Страница 8: ...nstalled for better air circulation 1 Fasten the filter cover at the air exit with the four screws 12c 2 9 x 9 5 2 Fasten the air conduction grid 8 with two of the screws supplied 12d 2 9 x 9 5 at the...

Страница 9: ...ion is inserted in the plug of the fan 4 Functional description The cooker hood has the following features Extraction air and recirculating air modes possible with extras Edging suction technology wit...

Страница 10: ...r any speed setting deactivation by means of briefly pressing the button T3 Speed setting on Third speed setting T4 Speed setting on flashing Top speed setting High power setting Suitable when a great...

Страница 11: ...ection by pressing and holding the T1 button 4 Let go of the button all five LEDs light up consistently 5 Within three seconds press the T1 button until the T1 and T4 LEDs begin to blink as acknowledg...

Страница 12: ...ghting unit For lighting up the hob with targeted halogen lamps Operated from the control panel of the hood 3 Control panel unit For switching the lighting and the motor of the hood on and off for reg...

Страница 13: ...odour filters if the hood has been installed in the recirculating air mode Check Before you carry out any repair work make sure that the Check steps to determine minor errors or faults have been carri...

Страница 14: ...control panel of the hood has not developed a fault Proceed as follows to replace a lamp or lamp mounting 1 Use an Allen key to loosen the four fastening screws in order to remove the cover of the lig...

Страница 15: ...by means of operating the respective lever 2 Remove the right hand self supporting metal grease filter 3 Loosen the screw which fastens the transformer support to the hood casing and remove the trans...

Страница 16: ...edge suction device by means of operating the respective lever 2 Loosen the screws that fasten the cover of the control panel to the inner support and remove the cover 3 Remove the two screws that fas...

Страница 17: ...l buttons on the left side of the control panel in order to release the unit Once the circuit board has been replaced re install the unit as follows Fasten the control unit once again onto the bracket...

Страница 18: ...roceed as follows to replace the main board 1 Open the hood and remove the right hand panel of the edge suction device by means of operating the respective lever 2 Remove the right hand self supportin...

Страница 19: ...ht hand panel of the edge suction device by means of operating the respective lever 2 Remove the left hand grease filter 3 Loosen the wing screw and remove the casing with the line filter circuit boar...

Страница 20: ...screws with which the main holder is fastened to the casing and remove the holder 4 Remove the front filter support sheet by screwing out the six screws that fasten the casing 5 Remove the side connec...

Страница 21: ...e frequency 230V 50Hz Appliance dimensions WxDxH 898 x 800 x 330mm Electrical connection 470W Halogen lighting 3 x 20W Air flow rate free blowing MIN setting MED setting MAX setting INTENSIVE 280m h 5...

Страница 22: ...22 Service Manual For internal use only 7 Circuit diagram...