8.11 Size 8 KFU 510 (160 to 400 kW, 525 V)
Type
KFU 510
--230
-290
-360
-450
-490
-560
Size
8
Output, motor side
Recommended motor shaft power
P
kW
160
200
250
315
355
400
Output current
I
A
eff.
230
290
360
450
490
560
Long-term overload current (60 s)
1)
I
A
eff.
345
435
540
675
735
840
Short-term overload current (1 s)
2)
I
A
eff.
420
520
650
810
880
1000
Output voltage
U
V
eff.
Maximum input voltage, three-phase
Protection
-
-
Short circuit / earth fault proof
Rotary field frequency
f
Hz
±500 Hz
3)
Switching frequency
f
kHz
2, 4, 8
4)
Output, braking resistor (external)
5)
Min. braking resistance
R
Ω
1,20
1,20
1,20
0,80
0,80
0,80
Recommended braking resistor
(U
dBC
= 770 V)
R
Ω
2,70
2,70
2,70
1,50
1,50
1,50
Imput. mains side
Mains current
6)
I
A
215
270
335
420
470
525
Mains voltage
7)
U
V
525
Mains frequency
f
Hz
50 (60)
Fuses
8)
I
A
315
350
450
550
630
700
Mechanical
Dimensions
HxWxD mm
1067 x 439 x 375
Weight approx.
m
kg
120
120
120
140
140
140
Ingress protection rating
-
-
IP20 (EN60529)
Connection terminals
A
mm
2
up to 2 x 240
Form of assembly
-
-
vertical
Ambient conditions
Energy dissipation
(2 kHz switching frequency)
P
W
3800
4500
5600
6300
6850
7900
Coolant temperature
T
n
°C
-25 … 45 (3K3 DIN IEC 60721-3-3)
Storage temperature
T
L
°C
-25 ... 55
Transport temperature
T
T
°C
-25 ... 70
Rel. humidity
-
%
15 ... 85, not condensing
If required by the customer, the switching frequency may be increased if the output current is reduced at the same time.
Comply with the applicable standards and regulations for this operating point.
Output current
9)
Frequency inferter nominal power
Switching frequency
2 kHz
4 kHz
8 kHz
160 kW
230
230
230
200 kW
290
290
290
250 kW
360
360
360
315 kW
450
450
450
355 kW
490
490
490
400 kW
560
560
560
1)
Power reduction with torsional frequencies below 10 Hz
2)
Only with torsional frequencies above 10 Hz
3)
Depending on switching frequency
4)
Reduction of switching frequency possible on certain conditions
5)
As an option, the frequency inverter of this size is available without internal brake transistor
6)
Rated value with recommended motor power, 525V mains voltage and mains inductance U
K
=4%
7)
Note that, in addition to AC 3x525V connection, AC 3x400V connection is also required, see Chapter 4.3
8)
Semiconductor fuses recommended (e.g. Bussmann Type 170M)
9)
Maximum current in continuous operation