![Küenle KFU 210 Series Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/kuenle/kfu-210-series/kfu-210-series_quick-start-manual_2009351054.webp)
KFU 210- / 410-
53
8.10 Size 8 KFU 410 (160 to 400 kW, 400 V)
Type
KFU 410
-305
-380
-475
-595
-645
-735
Size
8
Output, motor side
Recommended motor shaft
power
P
kW
160
200
250
315
355
400
Output current
I
A
eff.
305
380
475
595
645
735
Long-term overload current (60 s)
1)
I
A
eff.
460
570
715
895
970
1100
Short-term overload current (1 s)
2)
I
A
eff.
550
685
855
1070
1160
1330
Output voltage
U
V
eff.
Maximum input voltage, three-phase
Protection
-
-
Short circuit / earth fault proof
Rotary field frequency
f
Hz
±500 Hz
3)
Switching frequency
f
kHz
2, 4, 8
4)
Output, braking restor (external)
5)
Min. braking resistance
R
Ω
1,20
1,20
1,20
0,80
0,80
0,80
Recommended braking resistor
(U
dBC
= 770 V)
R
Ω
1,50
1,50
1,50
1,00
1,00
1,00
Input, mains side
Mains current
6)
I
A
280
350
440
550
620
690
Mains voltage
U
V
320 … 528
Mains frequency
f
Hz
45 … 66
Fuses
7)
I
A
400
500
630
700
800
900
Fuses as per UL
8)
in preparation
Typ
170M5*08
or
170M5*58
170M5*10
or
170M5*60
170M5*12
or
170M5*62
170M5*13
or
170M5*63
170M5*14
or
170M5*64
170M5*15
or
170M5*65
Mechanical
Dimensions
HxWxD mm
1067 x 439 x 375
Weight approx.
m
kg
120
120
120
140
140
140
Ingress protection rating
-
-
IP20 (EN60529)
Connection terminals
A
mm
2
up to 2 x 240
Form of assembly
-
-
vertical
Ambient conditions
Energy dissipation
(2 kHz switching frequency)
P
W
3800
4500
5600
6300
6850
7900
Coolant temperature
T
n
°C
-25 … 45 (3K3 DIN IEC 60721-3-3)
Storage temperature
T
L
°C
-25 ... 55
Transport temperature
T
T
°C
-25 ... 70
Rel. humidity
-
%
15 ... 85, not condensing
If required by the customer, the switching frequency may be increased if the output current is reduced at the same time.
Comply with the applicable standards and regulations for this operating point.
Output current
9)
Frequency inverter nominal
power
Switching frequency
2 kHz
4 kHz
8 kHz
160 kW
305
305
305
200 kW
380
380
380
250 kW
475
475
475
315 kW
595
595
595
355 kW
645
645
645
400 kW
735
735
735
1)
Power reduction with torsional frequencies below 10 Hz
2)
Only with torsional frequencies above 10 Hz
3)
Depending on switching frequency
4)
Reduction of switching frequency possible on certain conditions
5)
As an option, the frequency inverter of this size is available without internal brake transistor
6)
Rated value with recommended motor power, 400V mains voltage and mains inductance U
K
=4%
7)
Semiconductor fuses recommended (e.g. Bussmann Type 170M)
8)
For UL-compliant fusing, the specified Cooper Bussmann fuses must be used. * is a placeholder for assembly.
9)
Maximum current in continuous operation