KFU 210- / 410-
30
If the setup was changed, the “SEtUP” message will be displayed again.
Confirm this message by pressing the ENT key in order to continue the commissioning procedure.
After initialization, confirm the selected configuration by pressing the ENT key.
Select the connected machine via parameter Motor type 369.
NOTE
If the motor type is not entered correctly, the drive may be damaged.
Configure and display the parameters and contolling the inverter can be happen by the optional KP500. This will
be plugged on to the front side of the inverter.
Opertation Mode
Function
0 -
Unknown
The motor is not a standard type.
1 -
Asynchronous Three-phase asynchronous motor, squirrel cage
2 -
Synchronous
Three-phase synchronous motor
3 -
Reluctance
Three-phase reluctance motor
10 - Transformer
Transformer with three primary windings
Enter the motor data indicated on the rating plate in the following parameters.
No.
Description
No
Description
370
Rated Voltage
374 Rated Cosinus Phi
371
Rated Current
375 Rated Frequency
372
Rated Speed
376 Rated Mech. Power
Use the arrow keys to select the required parameter and edit the parameter value.
Use the ENT key to confirm the selected parameter and the parameter values entered..
The rated data of the motor are to be entered according to the specifications on the rating plate for the
motor connection type used (star or delta connection).
If the data entered deviate from the rating plate, the parameters will not be identified correctly. The
rated data is to be parameterized as per the motor rating plate. Consider the increased rated current of
the connected three-phase motor when the motor is switched from star to delta.
After input of the machine data, the calculation or examination of the parameters is
automatically started. The display changes over to "CALC" for a short time. If the
verification of the entered machine data is successful, the guided commissioning
procedure continues with the identification of the parameters (automatic measurement of
further machine data).
Note the warnings and error messages displayed during guided commissioning.
To ignore the warning messages, press the ENT key. The guided commissioning is continued. However, it is
recommended that the data be checked and corrected if necessary.
To correct the entered parameter values after the warning or error message, press the ESC key. Use the