COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S115
9Y1200192CRS0655US0
Name
Excessive PM4
Excessive PM5
ISO 14229
P-Code
P3007
P3008
J1939-73
SPN
3701
3701
FMI
16
0
DTC Name
Excessive PM4
Excessive PM5
Management Unit
for Detected Part
DPFPMEX3
DPFPMEX4
Detection item
• PM accumulation level4
• PM accumulation level5
DTC Set
Preconditions
• Battery voltage is normal
• Battery voltage is normal
DTC set parameter
• PM accumulation more than trigger level
(31000 mg)
• PM accumulation more than trigger level
(36000 mg)
Time to action or
number of error
detection
• Transient
• Transient
System Action
• Output limitation: Approximately 50 % of
normal condition
• Output limitation: Approximately 50 % of
normal condition
Behaviour During
Malfunction
• Insufficient output
• Insufficient output
Engine Warning
Light
• ON
• ON
Recovery from
error
• Diagnostic counter = zero
• Key switch turn OFF
KiSC issued 05, 2012 A