![Kubota V3800-CR-TE4 Скачать руководство пользователя страница 144](http://html1.mh-extra.com/html/kubota/v3800-cr-te4/v3800-cr-te4_diagnosis-manual_2008593144.webp)
COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S117
9Y1200192CRS0657US0
Name
Low coolant temperature in parked
regeneration
Parked regeneration time out
ISO 14229
P-Code
P3012
P3013
J1939-73
SPN
523589
523590
FMI
17
16
DTC Name
Low coolant temperature in parked
regeneration
Parked regeneration time out
Management Unit
for Detected Part
ST5TIMEUP
MNRGNTIMEUP
Detection item
• During regeneration mode, engine
warm-up condition is not satisfied
(coolant temperature is low)
• Time out error: regeneration incomplete
due to low temperature of DPF
DTC Set
Preconditions
• During parked active regeneration mode
• During parked active regeneration mode
DTC set parameter
• Engine coolant temperature stays below
65 °C (149 °F) for 1500 seconds or more
under parked regeneration
preprocessing process, and engine
coolant temperature stays below 65 °C
(149 °F) for 25 seconds or more under
parked regeneration burning process
• Regeneration process is not completed
within 2700 sec
Time to action or
number of error
detection
• Transient
• Transient
System Action
• None
• None
Behaviour During
Malfunction
• None
• None
Engine Warning
Light
• ON
• ON
Recovery from
error
• Diagnostic counter = zero
(Leaving from parked active
regeneration status)
• Diagnostic counter = zero
(Leaving from parked active
regeneration status)
KiSC issued 05, 2012 A