COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S264
(48) Exhaust Gas Temperature Sensor 2: Emergency High (DTC P3004 /
3246-0)
Behaviour during malfunction:
• Engine stops
• Inhibit cranking until down to 300 °C (572 °F)
Detection item:
• DPF outlet temperature (T2) high
DTC set preconditions:
• Exhaust gas temperature sensor T0, T1 and T2 are normal
• Battery voltage is normal
DTC set parameter:
• DPF outlet temperature (T2): 820 °C (1508 °F) or more
Engine warning light:
• ON
System action:
• Stop injection (Q = 0 mm
3
/st)
• Engine stop
• EGR stop
• Intake throttle 0 % open (Close)
• Inhibit starter relay activation until exhaust gas temperature reduces down to 300 °C (572 °F)
Recovery from error:
• Under 300 °C (572 °F) & key switch turn OFF
9Y1200192CRS0822US0
1. Check the Air Intake System
1. Check in accordance with "6.[1] AIR INTAKE SYSTEM
INSPECTION PROCEDURE". (Refer to page 1-S285)
IMPORTANT
• If the two errors occur from "Emergency exhaust gas
temperature sensor T0 high", "Emergency exhaust gas
temperature sensor T1 high", and "Emergency exhaust gas
temperature T2 high" at the same time, check the exhaust
gas temperature starting from a bigger number.
NOTE
• Check the clogging condition of the air cleaner. If it is very
dirty, replace the new one.
• Check if the suction hose of the turbo blower does not
come off. If the hose comes off, install it.
• Check the suction path for leaks. (Suction path joints,
suction pipes, hoses)
• Check the clogging condition of the fuel filter. If it is very
dirty, replace the new one.
• Check the installation of all exhaust gas temperature
sensors (T0, T1 and T2).
• Check the engine oil level.
• Check the engine coolant level.
9Y1200192CRS0931US0
OK
Go to "2. Check the Exhaust Gas Temperature".
NG
Repair in accordance with "6.[1] AIR INTAKE SYSTEM INSPECTION
PROCEDURE". (Refer to page 1-S285)
(1) Hose Clamp
(2) Hose
(3) Turbocharger
[A] M60 Series
[B] M-GX Series