![Kubota V3800-CR-TE4 Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/kubota/v3800-cr-te4/v3800-cr-te4_diagnosis-manual_2008593146.webp)
COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S119
9Y1200192CRS0659US0
Name
High frequency of regeneration
CAN2 Bus off
ISO 14229
P-Code
P3024
U0075
J1939-73
SPN
523602
523547
FMI
0
2
DTC Name
High frequency of regeneration
CAN2 Bus off
Management Unit
for Detected Part
RGNINTWRN
CANB2
Detection item
• Time interval from the end time to the
start time of the regeneration
• CAN2 +B / GND short circuit or high
traffic error
DTC Set
Preconditions
• Battery voltage is normal
• Key switch is ON
• Battery voltage is normal
• Key switch is ON
DTC set parameter
• Regeneration time interval within 30 min.
occurs three times continuously
• CAN2 Bus off
Time to action or
number of error
detection
• Transient
• 2 sec. or more
System Action
• Output limitation: Approximately 50 % of
normal condition
• EGR stop
• Forced Idle (Accelerator = 0 %)
Behaviour During
Malfunction
• Worsening exhaust gas performance
(NOx)
• Insufficient output
• Transmitted data is invalid
Engine Warning
Light
• ON
• ON
Recovery from
error
• Key switch turn OFF
• Key switch turn OFF
KiSC issued 05, 2012 A