COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S114
9Y1200192CRS0654US0
Name
Excessive PM3
ISO 14229
P-Code
P3006
J1939-73
SPN
3701
FMI
15
DTC Name
Excessive PM3
Management Unit
for Detected Part
DPFPMEX2
Detection item
• PM accumulation level3
DTC Set
Preconditions
• Battery voltage is normal
DTC set parameter
• PM accumulation more than trigger level (26000 mg)
Time to action or
number of error
detection
• Transient
System Action
• Output limitation: Approximately 50 % of normal condition
Behaviour During
Malfunction
• Insufficient output
Engine Warning
Light
• ON
Recovery from
error
• Diagnostic counter = zero
KiSC issued 05, 2012 A