![Kubota V3800-CR-TE4 Скачать руководство пользователя страница 105](http://html1.mh-extra.com/html/kubota/v3800-cr-te4/v3800-cr-te4_diagnosis-manual_2008593105.webp)
COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S78
9Y1200192CRS0618US0
Name
Rail pressure sensor abnormality
ISO 14229
P-Code
P0192
P0193
J1939-73
SPN
157
157
FMI
4
3
DTC Name
Rail pressure sensor: Low
Rail pressure sensor: High
Management Unit
for Detected Part
PCL
PCH
Detection item
• Ground short circuit of sensor / harness
• Failure of sensor
• Open circuit or +B short circuit of sensor
/ harness.
• Failure of sensor
DTC Set
Preconditions
• Battery voltage is normal
• Sensor supply voltage VCC# is normal
• Battery voltage is normal
• Sensor supply voltage VCC# is normal
DTC set parameter
• Voltage of rail pressure sensor is 0.7 V or
less
• Voltage of rail pressure sensor is 4.9 V or
above
Time to action or
number of error
detection
• Transient
• Transient
System Action
• Output limitation: Approximately 50 % of
normal condition
• Speed limitation (Accelerator limitation:
50 %)
• Rail pressure limitation:
Command pressure
≤
80 MPa
(820 kgf/cm
2
, 12000 psi)
• EGR stop
• Engine forcibly stopped 60 sec. later
• Output limitation: Approximately 50 % of
normal condition
• Speed limitation (Accelerator limitation:
50 %)
• Rail pressure limitation:
Command pressure
≤
80 MPa
(820 kgf/cm
2
, 12000 psi)
• EGR stop
• Engine forcibly stopped 60 sec. later
Behaviour During
Malfunction
• Insufficient output
• Worsening exhaust gas performance
• Worsening running noise
• Increase in white smoke
• Engine stops
• Insufficient output
• Worsening exhaust gas performance
• Worsening running noise
• Increase in white smoke
• Engine stops
Engine Warning
Light
• ON
• ON
Recovery from
error
• Key switch turn OFF
• Key switch turn OFF
KiSC issued 05, 2012 A