![Kubota V3800-CR-TE4 Скачать руководство пользователя страница 112](http://html1.mh-extra.com/html/kubota/v3800-cr-te4/v3800-cr-te4_diagnosis-manual_2008593112.webp)
COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S85
9Y1200192CRS0625US0
Name
Camshaft position sensor (G sensor) abnormality
ISO 14229
P-Code
P0340
P0341
J1939-73
SPN
723
723
FMI
8
2
DTC Name
No input of G sensor (Camshaft position
sensor) pulse
G sensor (Camshaft position sensor) pulse
number error
Management Unit
for Detected Part
GNOP
GPUM
Detection item
• Open circuit or short circuit of sensor /
harness
• Failure of sensor
• Open circuit or short circuit of sensor /
harness
• Failure of sensor
DTC Set
Preconditions
• Battery voltage is normal
• Sensor supply voltage VCC# is normal
• Engine is not stalled
• Battery voltage is normal
• Sensor supply voltage VCC# is normal
• Engine speed is 350 min
-1
(rpm) or
higher
DTC set parameter
• No recognition of G sensor pulse
• Pulse count per rotation is not
5 teeth
Time to action or
number of error
detection
• 10 times or more
• 10 times or more
System Action
• None
• None
Behaviour During
Malfunction
(Invalid G signal)
• Engine hesitates at start-up
(Invalid G signal)
• Engine hesitates at start-up
Engine Warning
Light
• ON
• ON
Recovery from
error
• Diagnostic counter = zero
• Diagnostic counter = zero
KiSC issued 05, 2012 A