COMMON RAIL SYSTEM
V3800-CR-TE4,V3800-CR-TIE4, DM
1-S112
9Y1200192CRS0652US0
Name
Exhaust gas temperature sensor 0:
Emergency high
Exhaust gas temperature sensor 1:
Emergency high
ISO 14229
P-Code
P3002
P3003
J1939-73
SPN
4765
3242
FMI
0
0
DTC Name
Emergency
Exhaust gas temperature sensor 0: High
Emergency
Exhaust gas temperature sensor 1: High
Management Unit
for Detected Part
EXTEMPT0
EXTEMPT1
Detection item
• DOC inlet temperature (T0) high
• DPF inlet temperature (T1) high
DTC Set
Preconditions
• Exhaust gas temperature sensor T0,T1
and T2 are normal
• Battery voltage is normal
• Exhaust gas temperature sensor T0,T1
and T2 are normal
• Battery voltage is normal
DTC set parameter
• DOC inlet temperature (T0): 700 °C
(1292 °F) or more
• DPF inlet temperature (T1): 715 °C
(1319 °F) or more
Time to action or
number of error
detection
• 2.0 sec. or more
• 9.0 min. or more
System Action
• Stop injection (Q = 0 mm
3
/st)
• Engine stop
• Inhibit starter relay activation until
exhaust gas temperature reduces down
to 300 °C
(572 °F)
• Stop injection (Q = 0 mm
3
/st)
• Engine stop
• Inhibit starter relay activation until
exhaust gas temperature reduces down
to 300 °C
(572 °F)
Behaviour During
Malfunction
• Engine stops
• Inhibitef cranking until down to 300 °C
(572 °F)
• Engine stops
• Inhibitef cranking until down to 300 °C
(572 °F)
Engine Warning
Light
• ON
• ON
Recovery from
error
• Under 300 °C (572 °F) & key switch turn
OFF
• Under 300 °C (572 °F) & key switch turn
OFF