The centering system needs to be reset with initial assembly or after having replaced brake
pads or single parts, respectively. Only in this way it is ensured that the gap between the
brake disk and the brake pad on the side of the counter plate is set to the right value and the
pad does not touch on any side.
The centering system has to be reset regularly with wear of the brake pads. For that purpo-
se repeat the complete chapter Setting/resetting of the centering system.
•
Measure the gap between the brake disk and the brake pad on the bottom side via a feeler gauge.
•
Set the gap to 0.5 mm or the figure x requested (see illustration 10), respectively, by screwing the hexagon
nut marked with 1 in illustration 11 either upwards or downwards.
•
Counter the hexagon nut with the hexagon nut marked with 2 in illustration 11.
•
Secure the pin (component 4.1) via the hexagon nut (component 4.3).
•
Screw the bolt (component 4.1) into the base plate (component 3.1). The screw depth in the base plate
must be 10 mm.
Illustration 10: Setting of gap
Illustration 11: Setting of centering system
4
Assembly
4.5 Setting/resetting of the centering system