39/IGNITION SYSTEM
104
300882-10
–
On the component side, measure the connection of the ignition coil against the
high voltage output.
Ignition coil
Resistance of secondary winding
at: 20 °C (68 °F)
5… 7.5 k
Ω
» If the measured value does not equal the specified value:
–
Change the ignition coil.
300957-10
–
Connect the special tool to the multimeter.
Peak voltage adapter (58429042000) (
Info
When using the peak voltage adapter, the measurement range of the multi-
meter must be set to DCV.
–
Place the red measuring lead of the special tool against ground. Place the black
measuring lead against the ignition coil input (blue/white cable).
–
Activate the kickstarter.
Ignition coil
Output voltage, primary winding
≥
150 V
» If the displayed value does not equal the specification:
–
Change the ignition coil.