39/IGNITION SYSTEM
103
–
On the cable harness side of plug
FD
, measure pin
7
against ground.
Resistance
∞
» If the measured value does not equal the specified value:
–
Check the wiring harness.
–
Change the generator.
–
On the cable harness side of plug
FD
, measure pin
9
against ground.
Resistance
∞
» If the measured value does not equal the specified value:
–
Check the wiring harness.
–
Change the generator.
–
Connect the special tool to the multimeter.
Peak voltage adapter (58429042000) (
Info
When using the peak voltage adapter, the measurement range of the multi-
meter must be set to DCV.
–
On the cable harness side of plug
FD
, measure pin
7
against pin
9
. Activate the
kickstarter.
Voltage - kickstarter confirmed
≥
40 V
» If the measured value does not equal the specified value:
–
Change the generator.
22.5
Checking the spark plug connector
300884-10
–
Measure the removed spark plug connector with a multimeter.
Spark plug connector
Resistance at: 20 °C (68 °F)
4.3… 5.7 k
Ω
» If the displayed value does not equal the specification:
–
Change the spark plug connector.
22.6
Checking the CDI controller
Info
Never check the CDI controller with a conventional measuring instrument. This can destroy highly sensitive electronic compo-
nents.
–
Check the cable and plug-in connection of the CDI controller. A functional check of the CDI controller is only possible on an igni-
tion test bench.
22.7
Checking the ignition coil
Condition
The fuel tank is removed.
–
Remove the spark plug connector.
–
Disconnect the ignition coil.
300881-10
–
On the component side, measure the connection of the ignition coil against ground.
Ignition coil
Resistance of primary winding at:
20 °C (68 °F)
0.25… 0.35
Ω
» If the measured value does not equal the specified value:
–
Change the ignition coil.
PartShark.com