9 Trouble-shooting
49 of 80
KSB Delta Primo
1983.811/02-EN
A B C D E
F G H
I
J
K L Possible cause
Remedy
6)
-
✘
-
-
✘ ✘
-
✘
-
✘
-
✘
Pressure transmitter set incorrectly
or defective
Check setting.
-
-
-
-
-
-
-
✘
-
-
✘ ✘
Pre-charge pressure of the
accumulator too low
Restore nitrogen cushion.
-
-
-
-
-
-
-
✘
-
-
✘ ✘
Defective accumulator
Check integrity/replace, if necessary.
-
-
-
-
-
-
✘
-
-
-
-
- Defective mechanical seal
Replace.
✘
-
-
-
-
-
-
✘
-
✘
-
- Suction-side pressure switch set
incorrectly or defective
Check setting.
-
-
✘ ✘ ✘
-
-
✘ ✘ ✘ ✘
- Defective check valve in the pressure
booster system
Check, replace sealing element as
necessary.
-
-
-
-
✘
-
-
-
✘ ✘
-
✘
Water extraction higher than stated
in the purchase order
Contact KSB.
-
✘
-
-
-
-
-
-
✘
-
-
✘
Motor protection switch triggered or
set incorrectly, or pump seized
Compare setting with the motor's
rating plate data.
-
-
-
-
-
-
-
-
-
-
✘
- Delay setting too short
Check setting.
-
✘
-
-
-
-
-
-
-
-
-
- Mains supply interrupted
Check and remedy defect/check fuse.
-
✘
-
-
-
-
-
-
-
-
-
- Control current fuse tripped (control
cabinet)
Determine cause and reset.
-
✘
-
-
-
-
-
-
✘
-
-
- Main fuse on (owner-supplied)
distribution board loose or blown;
fuses possibly too small or too fast
Check fuses and replace as necessary.
Measure the motor current.
-
-
-
-
-
-
-
-
✘
-
-
- Intermittent voltage fluctuations
Press reset and fault
acknowledgement key.
-
✘
-
-
-
-
-
-
-
-
-
- Phase failure
Check individual phases; replace
fuse, if necessary.
✘
-
-
-
-
-
-
-
-
-
-
- Inlet tank empty or float switch
defective / disconnected
Check and remedy defect.