ID.: 17-16-20-2979-10
48
3.2018
Error E07
– External Source Temperature Difference Error
In the case that the system is connected to an external source which the device may activate
via electric signal (oil / gas / pellet / wood furnace, external electric heater), the controller
checks the temperature of the external source after activation
.
If the temperature of the
external source is not
5°C higher than the temperature of water in the sanitary water tank
after three attempts of activation, the controller reports Error E07 and the circulation pump of
the external source is deactivated. External source operation needs to be checked. Should
external source be functioning flawlessly, service needs to be called. It is not possible to use
the external source until the error is removed.
Error E09: Controller supply voltage error
In the case E09 error is displayed on your device, the low-voltage device components
(device generator, electric heater, fan ...) cease to operate. The electronics displays error
E09 which means a fault in controller supply voltage. The error will be resolved after
establishing normal operation voltage and the device will start operating.
9.3 Errors of the OPTITRONIC 2 - WEB module (option):
Error E81
– Error on the connection between WEB module and device controller
To remove error, the cable connecting WEB module and the device (see "Instructions for
Error Removal") must be checked. The connection cable needs to be unplugged from the
module, checked, and plugged back in. If the cable is damaged or if the error persists after
reconnection, call service. Connection to the service Water Cloud is impossible or limited
until error removal.
Error E82
– General internal error of the WEB module
Error E83
– Memory medium error on the WEB module
Error E84 - Error on the communication interface of the WEB module
To remove the error, the WEB module has to be unplugged from power and re-plugged (see
"Instructions for Connection of Device Into Cloud"). If the error persists after module restart,
call service. Connection to the service Water Cloud is impossible or limited until error
removal.