ID.: 17-16-20-2979-10
28
3.2018
5.9 Electric Connection
Electric connection of the supply cable, external signal, additional temperature probe, and
additional heater is done under the cover on the front of the device. To access electrical
connections the front cover must be removed as shown below:
Figure 10: Front cover removal
WARNING
Connection of the device to the power grid must take place in accordance with
standards for connection to electrical grids. The device must be connected to the
electrical grid via a shutdown element, built into the electrical installation according
to valid regulations. The shutdown element must separate all contacts under the
conditions of overload category III.
DANGER
The device must be connected to the electricity supply where the RCD (FID) switch
of type A is installed.
All electrical connections are carried out on the bottom holder, where electrical pins with
cable release pins are prepared.
Содержание WP4 LF-502