A change of operation programme can be automatic by setting up a daily
schedule. Every daily schedule may have two time intervals. Every interval
has a set starting time, ending time, and programme of operation. In the time
outside the set intervals of the schedule, the device operates according to
basic programme.
Move between schedule setup windows with the key
.
Enter schedule
setting with the
key
.
Turn schedule
»
ON
« or »
OFF
«.
Set starting time of
schedule interval.
Set ending time of
schedule interval.
Set operation
programme in the
time of interval.
7.3.6.1
Weekly Schedule (option)
The schedule may be set for every day in the week separately. Every daily
schedule can have up to three time intervals. Every interval has a set starting
time, ending time, and programme of operation. In the time outside the set
intervals of the schedule, the device operates according to the basic
programme.
NOTE
To set and operate weekly schedules, the device needs to be
equipped with the Opritronic WEB module (option).
Move between schedule setup windows with the key
.
Enter schedule
setting with the
key
.
Pick the day of
the week
(1-Monday
7-Sunday).
Turn schedule
»
ON
« or
»
OFF
«.
Set starting time
of schedule
interval.
Set ending time
of schedule
interval.
Set operation
programme in
the time of
interval.
7.3.7 Ventilation Schedule
The devices with guided air, along with sanitary water heating, also enable
cooling and ventilation of rooms. Ventilation functions according to set
intervals of a ventilation schedule with set start and end times.
NOTE
To set and operate weekly ventilation schedules, the device
needs to be equipped with the Optitronic WEB module (option).