ID.: 17-16-20-2979-10
47
3.2018
appears, the device shuts down and Anti-Freeze program becomes active (
chapter 8.3.3)
.
Service has to be called to remove the error.
Error E05
– High Pressure Error
Should within 1 hour pressure in the cooling system of the generator be detected as too high
thrice (WARNING W03), the device shuts down and Anti-Freeze program becomes active
(chapter 8.3.3)
.
To remove the error, check if there is sufficient water in the water tank of the
device. If the error continues to be displayed in spite sufficient water, service has to be
called. Heating until the arrival of the service requires a manual activation of the backup
source
(chapter 7.3.10),
or additional source (
chapter 7.3.3
), if one is selected (
chapter
Содержание WP4 LF-502
Страница 53: ...ID 17 16 20 2979 10 53 3 2018 ...
Страница 54: ...ID 17 16 20 2979 10 54 3 2018 ...
Страница 55: ...ID 17 16 20 2979 10 55 3 2018 ...