ID.: 17-16-20-2979-10
15
3.2018
5. Installation
The lowest height of ceiling in the room must be 2500. The device is made so that it takes
heat from surrounding air or sucks it through air channels and blows it into neighbouring
rooms or the environment. The device may be installed in the following ways.
Figure 1: Suction and exhaust in the same room
(e.g. pantry cooling).
Figure 2: Suction of the outside air, exhaust into the surroundings
.
Figure 3: Suction and exhaust into neighbouring room (e.g. pantry cooling).
The most common placement of the heat pump is such, that the air is sucked from areas,
where there is a lot of waste heat. This air has a part of its heat removed, then released into
the surrounding. Air in kitchens, laundry rooms, sanitary facilities often contains unpleasant
odours, so it is blown into the environment. Thereby we must be careful that the air flows and
pressures in spaces are evened out, which must be ensured by the projecting engineer for
the ventilation.