NOTE!!!
All activities associated with connecting the device to the gas installation should be carried out with
the power disconnected. The insert installation can only be done by a qualified fitter/technician
with appropriate licences.
NOTE!!!
It is absolutely forbidden to use open fire during the installation process of the gas insert. Failure to
follow instructions could result in fire or explosions, causing severe damage, bodily injury or even
death.
Tightness test
After connecting the system to the gas network it is essential to check the tightness of the
connections made with a special sensor. In the case of leaks, shut off the gas supply shut-off valve
and repeat the steps involved in installing various parts of the system.
POWER SUPPLY CONNECTION
NOTE!!!
Connect the power supply only after connecting the combustion air system and any gas
control system components.
The B6R-R8U receiver is powered by four 1.5V AA batteries. Pay special attention to locate the wiring
connecting the gas control and the receiver away from hot parts of the fireplace. The need to replace
the batteries in the remote control is indicated by the indicator displayed in the upper right corner of
the display, while short beeps periodically appearing for three seconds immediately after starting the
firing process in the fireplace indicate the need to replace the batteries in the receiver. Used batteries
located in the receiver can overheat, spill or even explode. Do not use batteries that have been
exposed to the sun, moisture, heat or vibration. Install only batteries of the same type and the same
manufacturer. Do not install new batteries with worn ones. The kit can optionally include the G60-
ZB90 power module. This module is powered by four 1.5V AA batteries and should be connected
directly to the receiver in the place of the AC adapter connection. The additional power supply module
eliminates the need for batteries in the receiver. Optionally, customers can buy a cable connecting the
interrupter block and the receiver for the gas control system, equipped with a switch. The switch also
protects the system against uncontrolled flow of gas through the controller.