IMPORTANT

:

READ

 

THIS

 

MANUAL

 

BEFORE

 

INSTALLING

 

AND

 

USING

 

THIS

 

FIREPLACE

GAS

 

FIREPLACE

 

MODEL

 

961

 

DIRECT

 

VENT

INSTALLATION

 

INSTRUCTIONS

This appliance has been tested to & complies with ANSI Z21.88-2002·CSA 2.33-M02 ‘VENTED GAS FIREPLACE
HEATER’.  Installation must conform with local building codes, or, in the absence of local building codes, with the
national fuel gas code, ANSI Z223.1- NFPA 54 (Current Edition).  Approved for U.S. Installations only.

SPECIFICATIONS

Height:  31 1/8”  

 Width: 51 5/8"

Back Width: 35 1/4"   Depth:  18 1/2” 

Flue Size:  4” exhaust

      7” intake

         

Figure 1

Do not use this fireplace if any part has been under
water.  Immediately call a qualified service
technician to inspect this appliance and to replace
any part of the control system and any gas control
which has been under water.

COMMONWEALTH OF MASSACHUSETTS

INSTALLATIONS

WARNING: This Product Must Be Installed By A Licensed
Plumber Or Gas Fitter When Installed Within The
Commonwealth of Massachusetts.

IMPORTANT: Installation of a CO detector is required in
the fireplace room.

WARNING: DO NOT REPLACE THIS BURNER WITH
ANY OTHER SIZED BURNER.  REPLACEMENT WITH
AN UNAUTHORIZED BURNER CAN RESULT IN
TEMPERATURES EXCEEDING THE LIMITS FOR THIS
FIREPLACE AND VOID YOUR WARRANTY.

DUE TO HIGH TEMPERATURES, THIS FIREPLACE
SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY
FROM FURNITURE AND DRAPERIES.

YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN THE SAME ROOM
AS THIS FIREPLACE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE TEMPERATURES
AND SHOULD STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.
CLOTHING OR OTHER FLAMMABLE MATERIAL
SHOULD NOT BE PLACED ON OR NEAR THE
APPLIANCE.

MASONRY CONSTRUCTION:  A lintel, PART #788B,
must be used to support the added weight when
masonry construction is used.  See page #19 for
additional information.

IMPORTANT:

DO NOT PLACE FACING MATERIAL

OVER THE EXTERIOR FACE.  THE FACE WILL
EXPAND WHEN HEATED AND WILL CAUSE
CRACKING OF THESE MATERIALS. FAILURE TO
FOLLOW THESE INSTRUCTIONS WILL VOID  YOUR
WARRANTY.

Содержание 961 DV

Страница 1: ...ht any appliance Do not touch electrical switches do not use the phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppliers instructions If you cannot r...

Страница 2: ...0 Fan Installation 11 12 Minimum Maximum Gas Supply Pressure Run the Gas Line 13 14 Millivolt Board Removal Installation 14 16 Log Installation 17 Wall Switch Thermostat Remote Control Installation 18...

Страница 3: ...m and battery back up may be installed on the next adjacent floor level In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall...

Страница 4: ...e manufacturer of Product Approved side wall horizontally vented gas equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements s...

Страница 5: ...en Installed Within The Commonwealth of Massachusetts IMPORTANT Installation of a CO detector is required in the fireplace room WARNING DO NOT REPLACE THIS BURNER WITH ANY OTHER SIZED BURNER REPLACEME...

Страница 6: ...ow instructions included with the Simpson Dura Vent DV GS for position of chimney The 923 C adaptor must be used 6 All clearances to combustible requirements must be maintained Follow clearance requir...

Страница 7: ...not left the fireplace may make a loud banging noise when it heats up or cools down 10 Cut an opening for the wall thimble 9 x 9 The top of this opening must be a minimum of 47 1 4 above the height o...

Страница 8: ...ng used a lintel part 788B must be used over the top of the fireplace to support the added weight NOTE Provide for a minimum of 6 152 mm of clearance in front of the lower grill This will provide adeq...

Страница 9: ...TING REQUIREMENTS IMPORTANT This fireplace is approved for use only with one of the following direct vent systems HORIZONTAL TERMINATIONS 700 SERIES DIRECT VENT TERMINATION KITS Used for horizontal te...

Страница 10: ...izontal runs up to 2 ft must have a minimum vertical rise of 17 EXAMPLE 2 If the horizontal run is 8 ft the vertical rise required is 28 EXAMPLE 3 If the horizontal run is 21 ft the vertical rise requ...

Страница 11: ...ted soffit 12 E S Outside inside corner 12 F S Meter Regulator Not to be installed above within 3 ft horizontally from the center line of the regulator S Service regulator vent outlet 3 ft radius S No...

Страница 12: ...install the restrictor refer to Figures 7A 7B and bend the tabs up far enough approximately 80 degrees so that when positioned into the exhaust pipe will create tension to hold itself in place Do not...

Страница 13: ...7 pipes onto the previous extension kit Referring to Figure 9 7 Apply a liberal bead of exterior sealant around the outer edge of the termination kit box A and from the outside place the exterior wall...

Страница 14: ...m and is available from your dealer Follow the installation instructions included with the 923 C adaptor AND chimney system This chimney system may be purchased from your local dealer Maximum vertical...

Страница 15: ...t fan assemblies with magnetic limit switch already mounted 2 Components package 4 nuts installation instructions NOTE To wall mount the speed control you will need to purchase a speed control assembl...

Страница 16: ...9 Re install the electrical access panel and secure 10 Place the thermostatic control switch with magnet on the bottom of the firebox 11 Plug the fan cord E into the receptacle in the electrical box...

Страница 17: ...d flexible gas line will connect CAUTION The manual shut off valve or flexible gas tubing must not extend outside of the fireplace cavity See the WARNING label affixed to the flexible tubing for addit...

Страница 18: ...gas valve The right pressure tap is the manifold pressure and the left pressure tap is the incoming pressure FOLLOW INSTRUCTIONS ON PAGE 24 OF THIS MANUAL G MILLIVOLT BOARD BURNER ASSEMBLY REMOVAL IN...

Страница 19: ...Re install the pilot shield Figure 11D 4 Re install the burner cover aligning the mounting holes in the burner brackets to the corresponding mounting studs on the bottom of the millivolt board Figure...

Страница 20: ...t notched out section of the bracket as shown in Figure 12B This is approximately 5 8 opened Figure 12A The lever may be adjusted in small increments by pulling the lever down slightly and sliding it...

Страница 21: ...notches to the burner cover Figure 13B 3 Place the center logs BW6 BW7 over the base BW7 logs aligning the holes and or notches in the logs BW6 to the base logs Figure 13B BW4 BW5 Figure 13B 4 Brush r...

Страница 22: ...iate connector to each wall switch thermostat wire and connect to the top and bottom terminals on the gas valve REMOTE CONTROL USERS Follow instructions included with the remote control IMPORTANT The...

Страница 23: ...ound Attach the appropriate set for your application Align the 3 holes on each side of the fireplace to the slots on each trim piece and secure with the screws provided 3 ea Side Figure 15 3 COMPLETE...

Страница 24: ...CLOSED POSITION IN PARTIAL OPENED POSITION 5 START UP THIS STEP SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER OR SERVICE TECHNICIAN A Make sure the burner tube is properly seated over the burner orific...

Страница 25: ...wer hole and release The grill will set down into place Lower grills See Figure 18 A The lower grills attach to the hinges A located at the bottom of the fireplace B Remove the 1 4 nuts B from the low...

Страница 26: ...t the thermostat if used to the lowest setting 3 Turn off all electric power to the appliance 4 Push in control knob A slightly and turn clockwise to OFF Gas Valve NOTE Knob cannot be turned from PILO...

Страница 27: ...19 NOTE A PAINT SMELL WILL OCCUR DURING THE FIRST FEW HOURS OF BURNING IT IS RECOMMENDED TO LEAVE THE FAN OFF DURING THIS PERIOD AS THIS WILL SPEED UP THE PAINT CURING PROCESS INITIAL BURN PERIOD DUE...

Страница 28: ...d ON NOTE If manifold pressure reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure check TO CH...

Страница 29: ...x near the top and remove the baffle 6 Examine proper sealing of the vent system 7 Re install the baffle and nuts Tighten nuts only enough to secure baffle Baffle must be able to float as the fireplac...

Страница 30: ...E SOLUTION 1 No spark when piezo The nut which holds the piezo Tighten nut button is depressed in place is loose Wire on back of piezo button Put wire back into place is loose or off Wire from piezo t...

Страница 31: ...ay due to pinching of wires need loosening to remove pinched wire Generator is not producing enough Replace generator millivolts to operate burner Wall switch remote control or Connect properly or dis...

Страница 32: ...1A Natural Gas Conversion Kit 700 093 Thermocouple OCK S50A LP Gas Conversion Kit 700 094 Pilot Orifice Natural Gas 700 095 Pilot Orifice LP Gas 936 035 Burner Tube 961 E35 Burner Cover with brackets...