Page 22
LIGHTING AND SHUTDOWN PROCEDURES
NOTE: Prior to lighting, check all fittings for leakage. This is accomplished by applying soapy water on all
connections made. If there is any leakage, bubbles will appear at the point of connection. If bubbles occur,
tighten the fittings until the bubbles no longer appear.
IMPORTANT: TEST ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE.
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut
off valve during any pressure testing of the gas line at test pressures equal to or less than 1/2 psig (3.5 kPa).
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas
valve. The right pressure tap is the manifold pressure and the left pressure tap is the incoming pressure. Follow
instructions on page #24 for checking these pressures.
NOTE: Read 1-8 before lighting the fireplace for the first time. Refer to Figure 19, page #23.
1. Open the lower grill by grasping the center of the top louver, and pull out and down.
2. Set the thermostat, if used, to the lowest setting.
3. Turn off all electric power to the appliance.
4. Push in control knob (A) slightly and turn clockwise to "OFF”.
Gas Valve
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow the safety information in the
fireplace installation manual. If you don't smell gas, go to the next step.
6. Find the pilot - follow metal tube from gas control. The pilot is behind the burner tube inside the combustion
chamber.
7. Turn the control knob on gas valve counterclockwise to "PILOT".
8. Push in the control knob all the way and hold in. Press the piezo
igniter button (B).
S.I.T. Pilot
The pilot will generally light with two or three pushes on the igniter. Hold the knob in for about one (1)
minute after the pilot is lit. Release knob and it will pop back out. Pilot should remain lit. If it goes out,
repeat steps 4 through 8.
*
If knob does not pop out when released, stop and immediately call your service
technician or gas supplier.
*
If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and
call your service technician or gas supplier.
9. Turn gas control knob counterclockwise to
"ON".
10. The burner can now be turned ‘ON’ or lit by depressing the bottom of the ON/OFF rocker switch (C) located
beside the valve
OR
by setting the thermostat or remote control to the desired setting.