THIS INSERT IS APPROVED FOR INSTALLATION IN MASONRY AND FACTORY-BUILT SOLID FUEL BURNING FIREPLACES.
EXISTING FIREPLACE SPECIFICATIONS
PAGE 8
(A) Height: ……………………………………..28" (711mm)
(B) Front Width:……………………………….38-1/2" (978mm)
(C) Depth:………………………………………16-1/2" (419mm)
(D) Back Width:………………………………..26-3/4" (697mm)
All dimensions are minimum requirements
EXISTING FIREPLACE REQUIREMENTS
The existing fireplace & chimney must be clean and in good working order and constructed of non-combustible materials.
A gas line must be able to be installed to insert.
Provisions made to provide electrical power to operate insert fan and thermostatic control (if used).
Any chimney clean-outs must fit properly.
Existing Chimney must be comprised of one of the following: Factory built chimney: 8” (203mm) minimum inside diameter.
Masonry Chimney: 6" x 8" minimum inside diameter.
Existing Chimney Height:
Minimum: 11ft. (3.35m)
Maximum: 40ft. (12.19m)
Determine length of your existing chimney:
1. Remove and discard existing chimney cap.
2. Measure from fireplace base to top of chimney.
Subtract 24” (610mm).
This is total length of co-linear flexible aluminum required.
MEASUREMENT FROM FIREPLACE BASE TO TOP OF CHIMNEY:____________
LESS 24" (610mm) (HEIGHT OF INSERT):
-24" (610mm)
TOTAL CHIMNEY LENGTH REQUIRED:
____________
NOTE: It is helpful to have two people complete next step in determining
chimney height.
EXISTING FIREPLACE MINIMUM OPENING REQUIREMENTS
CAUTION: This appliance must not be connected to or joined with any other
chimney flue serving another appliance.
Figure 8a