#OCK-S30A NAT GAS CONVERSION KIT
#OCK-S47A LP GAS CONVERSION KIT
This kit includes:
(1) Valve Conversion Instructions
(1) Gas Pilot Injector (1) Gas Conversion Label
(1) Burner Orifice #30-NAT / #47 LP
(1) Gas Label
(1) Pilot Orifice (BL22N-NAT / BL14LP-LP) (1) Pilot Conversion Instructions
WARNING: SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ANY ELECTRICAL POWER.
PREPARE FIREPLACE:
1. Turn fireplace off by pushing in and turning gas control knob clockwise to OFF position.
2. Remove glass frame assembly*, logs*, and burner assembly* from fireplace insert.
CONVERT PILOT ASSEMBLY:
1.
Using a 7/16” wrench, loosen and remove pilot hood by turning counter
-clockwise.
2. Remove pilot orifice located inside pilot housing. Install pilot orifice included with kit.
3. Re-attach pilot hood. Tighten with wrench, making sure hood is centered between thermopile and thermocouple.
PILOT ORIFICE
PAGE 35
CONVERSION KIT INSTRUCTIONS
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and
all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion or production of carbon monoxide may result, causing property damage, personal injury
or loss of life. The qualified service agency is responsible for proper installation of this kit. The installation is not proper and
complete until operation of the converted appliance is checked as specified in the instructions supplied with the kit. Refer to
appliance owner‟s manual or product data plate for proper inlet and manifold pressure adjustments and orifice sizing.
NAT
LP
REPLACE BURNER ORIFICE:
1. Remove existing orifice cap and replace with orifice cap included with kit, making sure to tighten cap securely.
CONVERT HI/LO REGULATOR ON GAS VALVE:
1. Follow instructions included with kit to convert gas valve.
COMPLETE THE CONVERSION:
1. Adjust venturi on burner assembly to by loosening screw, adjusting cap and retightening screw.
CORRECT SETTINGS:
NAT: 3/16” (5mm) open LP: 1/2” (13mm) open
2. Re-install burner assembly into fireplace, checking to ensure burner venturi is properly seated over burner orifice and pilot hood is
above burner assembly as shown below.
3. Re-install pilot shield.
4. Re-install logs*.
5. Light pilot and turn burner on*.
6. Check for leaks at all connections, whether field or factory made.
7. Test both inlet and manifold pressures*.
* Refer to installation manual if necessary.
Figure 37a
Содержание 911-XXL
Страница 38: ...PAGE 37 LIMITED WARRANTY...
Страница 39: ...PAGE 38 LIFETIME WARRANTY...