GAS LINE CONNECTION
911XXL / 91XXL-RAD
NATURAL GAS
LP GAS
MINIMUM INLET GAS PRESSURE
5.0 inches W.C. (7.0 W.C. recommended)
11.0 inches W.C. (recommended)
MAXIMUM INLET GAS PRESSURE
10.5 inches W.C.
13.0 inches W.C.
MANIFOLD PRESSURE (HI)
3.5 inches W.C
10.0 inches W.C.
MANIFOLD PRESSURE (LO)
1.7 inches W.C.
6.5 inches W.C
ORIFICE SIZE
#30
#47
INPUT BTU/hr.
42,000
42,000
MINIMUM INPUT BTU/hr.
29,500
30,000
PAGE 12
IMPORTANT: For high altitude installations, consult local gas distributor or authority having jurisdiction for proper rating methods.
NOTE: If installing this insert into minimum opening dimensions, the gas line may need to be run after placement due to space
limitations.
If installing this gas fireplace insert into a factory-built fireplace and the factory-built fireplace has no access hole provided, an access
hole of 1 ½"(38 mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This
access hole must be plugged with non-combustible insulation after the gas supply line has been installed.
IMPORTANT: Do not run gas line in a manner that would obstruct fan operation
This fireplace is manufactured for use with Natural Gas. An LP conversion kit is included with this fireplace.
Follow instructions included with conversion kit if converting to LP gas.
GAS CONVERSION
CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.
If not, follow ANSI 223.1.
Commonwealth of Massachusetts: Installation must be done by a licensed plumber or gas fitter.
IMPORTANT:
The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.
ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and
in accordance with the requirements of the ANSI Z223.1 installation code.
NOTE: A listed (and Commonwealth of Massachusetts approved) 12” (305mm) T- handle manual shut-off valve and flexible gas
connector (included) are connected to the 1/2” (13mm) control valve inlet. If substituting for these components, please
consult local codes for compliance.
NOTE: This fireplace is equipped with a 3/8”(10mm) x 18” (457mm) long flexible gas connector and manual shut-off valve. The gas
line should be run to the point of connection where the shut-off valve and flexible gas line will connect.
NOTE: The appliance and its individual shutoff valve must be disconnected from gas supply piping system during any pressure
testing of that system at pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any
pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).
NOTE: For high altitude installations, consult local gas distributor or authority having jurisdiction for proper rating methods
.
#911XXL-RAD owners
: If installing optional fan kit #XXL-028, please do so now before connecting gas line.