33
EN-114B_f.1294
Indoor module: Main board (operating components 230 V ~)
■
The specified power is the recommended connected load
■
The sum of the power of all components directly connected to the regulator heat
pumps (e.g. pumps, valves, fault reporting devices, contactors): 1000 W. If the total
power <1000 W, the power of a single component (e.g. pump, valve, signaling device,
contactor) may be higher than the set value. The permissible power of the respective
relay must not be exceeded.
■
The specified current value is the maximum switching current of the switching contact.
Take the total current of 5 A. Setting the required parameters during start-up.
Plug 211
Clamps
Function
Description
211.2
Secondary pump
Connection parameters
■
Power: 140 W
■
Voltage: 230 V ~
■
Max. contact current: 4 (2) A
■
Connect the controller in series
temperature limiter maximum
temperature the heating circuit of
the installation underfloor heating
(if is installed).
Secondary pump is connected
factory. Connect the regulator
temperature provided by investor.
211.3
Flow heater control DHW,
grade 1
211.4
■
three-way diverter valve
"Heating / Warm DHW "
■
Pump for charging the
exchanger DHW
■
two-way cut-off valve
Connection parameters
■
Power: 130 W
■
Voltage: 230 V ~
■
Max. contact current: 4 (2) A
Note
Depending on the version of the
installation, no all components are
mounted.
211.5
Only for the heat pumps with
cooling function: three-way
diverter valves to bypass the
buffer tank DHW in cooling mode
Connect the three-way diverter valves
in parallel. Connection parameters
■
Power: 10 W
■
Voltage: 230 V ~
■
Max. contact current: 4 (2) A