42
Clamps
Function
Description
Connection:
■
Serial connection, if available are
both safety components
■
Fit the bridge, if there is no avail-
able component security.
X40.L1
Electrical connection of the con-
troller heat pumps:
Phase L1
X40 Cable connection pro
-
tective
X40.N Connection for neutral
conductor
electrical connectio 230V~
Indoor module: Low voltage PCB (low voltage connections)
Setting the required parameters during commissioning.
Sensors
Plug
Sensor
Type
F0
Outdoor temperature sensor
NTC 10 kΩ
F4
Temperature sensor in the buffer cylinder
NTC 10 kΩ
F6
(X25.5/X25.6) Upper water temperature sensor in the DHW exchanger NTC 10 kΩ
F7
(X25.7/X25.8) Lower water temperature sensor in the DHW exchanger NTC 10 kΩ
F11
Humidity switch 24 V
or bridge
Note
■ cooling water: If cooling is done with several heating /
cooling circuits for each heating / cooling circuit must
be installed humidity switch. Several humidity switches
connect in series.
■ If the humidity switch 230 V ~ (connection to X3.8 /
X3.9) is used during cooling, fit the bridge, otherwise
the heat pump will not turns on ("CA Primary Security
Device" message).
-