53
EN-114B_f.1294
M
PCRK
TZAS1
TPOK
ZM
CWU
PM
HPSI
SWPC
PI
ZW
PO
M2/HC2 A1/HC1
NW co
ZA EA
NW cwu
ZB
ZN
FO
SVK
TBUF
SKK
HP.FTP
HPSO
TZAS2
TZEW
PO
An exemplary diagram of an installation with a plane heating circuit, radiator, heating
/ cooling water buffer, hot utility water tank and a cooling circuit with a fan coil.
HPSO - heat pump (outdoor unit)
HPSI - hydraulic module (heat pump indoor unit)
SKK - cooling circuit
M2/HC2 - plane heating
A1/HC1 - radiator heating
HP.HS.24 - humidity switch for 1 cooling circuit
HP.HS.230 - humidity switch in case of more than 1 cooling circuit (for switching off the circulation pump
in the cooling circuit)
TZM - temperature sensor of the medium in the surface heating circuit (WE-019/01)
PM - plane heating circuit pump
ZM - mix valve
PO - circulation pump
HP.FTP - frost protection thermostat
FO - desilter filter
TZAS1 - upper cylinder temperature sensor (WE-019/01)
TZAS2 - lower cylinder temperature sensor (WE-019/01)
TPOK - room temperature sensor (WE-033/02)
TZEW - outdoor temperature sensor (WE-027)
SWPC - DHW cylinder
SVK - DHW / cooling water buffer
PCRK - DHW circulation pump
TBUF - buffer temperature sensor (WE-019/01)
CWU - DHW
ZW - cold water
NWco - CH expansion vessel
NWcwu - DHW expansion vessel
ZA - anti-contamination valve EA class
ZB - safety valve
ZN - relief valve
Содержание HPS Z Series
Страница 1: ...HPS Z Assembly and operating instructions Original instructions Heat Pump ...
Страница 44: ...44 Indoor module Laying electrical wiring to the space connection ...