1. Familiarising yourself with this user's manual will allow the correct installation and
operation of the device, ensuring its long-term and reliable operation.
2. The appliance shall be installed in accordance with national wiring regulations
3. Efficient and made in accordance with PN-IEC 60364 electrical installation.
4. The appliance may only be installed and operated in closed heating systems according
to EN 12828, taking into account the relevant installation, service and operating
instructions.
■
Work on the refrigerant circuit may only be carried out by authorised refrigeration
engineers.
■
The system must be commissioned by the system installer or a qualified person
authorised by the installer.
5. Inadequate environmental conditions may damage the installation and endanger
the safety of operation (avoid air pollution through chlorine-alkanas contained e.g.
in paints, solvents and cleaners, avoid constant high humidity e.g. due to frequent
drying of washing).
6. Installation of the appliance and execution of the electrical and hydraulic system
shall be entrusted to a specialized service establishment and strictly adhere to the
instructions for installation and operation of the device.
7. All installation work must be carried out with the electricity and water supply cut off.
8. As a result of electrostatic discharge, sparks may appear that may ignite the leaking
refrigerant (R32). Before carrying out work, touch grounded objects, e.g. heating or
water pipes, to discharge static loads.
9. Hot surfaces can cause burns.
10. Direct contact with liquid and gaseous refrigerant can cause serious damage to
health.
11. The electrical installation shall be equipped with differential current protective devices
and means of ensuring that the device is disconnected from a power source at
a distance between the contacts of all poles of not less than 3 mm.
12. The heat pump is a surge-sensitive device and the electrical system must include
surge protection devices.
13. In the event of an open fire, there is a danger of burns.
14. The refrigerant is air-displacing, colourless, embarrowing gas.
■
R32 forms a combustible mixture in combination with air.
■
R410A is not flammable.