140
•
Power: M12 A-Code 4-pin Male
•
100 Base-TX: 2-pair Cat.5E / Cat.6 FTP/STP cable, EIA/TIA 568B
100-ohm, 100Meters
•
1000 Base-T: 4-pair Cat.5E/Cat.6 FTP/STP cable, EIA/TIA 568B
100Ohm, 100Meters
It is recommended uses FTP/STP cable for the railway on-board
application
RS-232 & USB
M12 A-Code female 8-pin connector
•
RS-232: TxD (Pin-1), RxD (Pin-2), Signal Ground (Pin-3)
•
USB Host: USB-DATA+ (Pin-5),USB-DATA- (Pin-6), USB-5V(Pin-7),
USB-GND (Pin-8)
LED Indicators
100Mbps (Port 1~7): Link (Green on)/Activity (Green Blinking)
1000Mbps (Port 8~10): Link (Green on)/Activity (Green Blinking) PoE
(IEEE 802.3af/ Green): Power forwarding (Green on), PoE Detection
(Green Blinking) PoE (IEEE 802.3at/ Blue): Power forwarding (Blue on),
PoE Detection (Blue Blinking)
Power: System Power Ready (Green on)
Sys: System Ready (Green on)
System Updating (Green Blinking)
R.S.: Ring Normal(Green on)/ Wrong ring port connective(Green
blinking)
Ring abnormal (Amber on)/ Device’s ring port disconnect (Amber
blinking)
Power Requirement
System Power
•
JetNet 6910G-M12 HVDC
Typical Input voltage: DC 110V (Un), Variation voltage 77V
(0.7Un)~137.5V (1.25Un)
•
JetNet 6910G-M12 LVDC
Typical Input voltage: DC24V (Un), Variation voltage 16.8V
(0.7Un)~30V (1.25Un)
Power consumption
HVDC: 25Watts without PoE/PD loading
LVDC: 20Watts without PoE /PD loading
Mechanical
Installation
Wall Mounting
Содержание JetNet 6910G-M12 Series