114
short circuit.
Dry Output
Relay continuous perform On/Off behavior with
different duration.
Port Event
Warning Event is sent when…..
Link-Up
The port is connected to another device
Link-Down
The port is disconnected (e.g. the cable is pulled out,
or the opposing devices turns down)
Once you finish configuring the settings, click on Apply to apply your configuration.
4.12.2
SysLog Configuration
System Log is useful to provide system administrator locally or remotely monitor switch
events history. There are 2 System Log modes provided by JetNet 6910G-M12, local mode
and remote mode.
Local Mode: In this mode, JetNet 6910G-M12 will print the occurred events selected in the
Event Selection page to System Log table of JetNet 6910G-M12. You can monitor the
system logs in [Monitor and Diag] / [Event Log] page.
Remote Mode: The remote mode is also known as Server mode in JetNet 6910G-M12. In
this mode, you should assign the IP address of the System Log server. JetNet 6910G-
M12G will send the occurred events selected in Event Selection page to System Log server
you assigned.
Both: Above 2 modes can be enabled at the same time.
Once you finish configuring the settings, click on Apply to apply your configuration.
Note: When enabling Local or Both modes, you can monitor the system logs in [Monitor
and Diag] / [Event Log] page.
4.12.3
SMTP Configuration
Jet 6910G-M12 supports E-mail Warning feature. The switch will send the occurred events
to remote E-mail server. The receiver can be notified by E-mail. The E-mail warning
mechanism conforms to SMTP standard.
This page allows you to enable E-mail Alert, assign the SMTP Server IP, Sender E-mail,
and Receiver E-mail. If SMTP server requests for authorizations, you can also set up the
username and password in this page.