600B SERIES MAINTENANCE MANUAL
JULY 2016 - V1.0
PAGE 36
Bellows
Description and Parts Breakdown
Individual Components
Description
Quantity
Part #
Bellows
1
10-230
Hose clamp
2
10-336
Inspection
Look for any cracks, holes, tears or a broken seal.
Look for large amount of corrosion on the surface of material or excessive wear.
Removal & Installation - Bellows
NOTE
:
Sterndrive must be removed for removal and installation of bellows.
Remove U-joint bellows from gimbal housing by loosening the two (2) hose clamps (10-336).
Position ground clips on bellows.
Position u-joint bellows with “TOP” mark facing upwards and install u-joint bellows on gimbal housing
flange and position clamp. Torque to 30-40 lb. in. (3.4 - 4.5 Nm).
NOTE
: When ordering the bellows (10-230), the two (2) hose clamps (10-336) are included.
IMPORTANT:
Be sure that the bead on the inner mating surface of bellows is positioned in the groove on
the gimbal-housing flange.
Bellows
10-230
Hose Clamp
10-336
Chapter 3 - Complex Maintenance