- 10 -
D
Connection
CAUTION, risk of electric shock.
The power connection of the awning shall
be performed by a qualified technician only. To be installed under effective
regulation.
●
Make sure that the power supply corresponds to the appliance's specifications (
Technical
data
). Interrupt power supply. Connect the cables in the terminal as follows.
Colour of cable
Yellow/green
Blue
Brown
From
To
Awning
Earth
Neutral
Live
Operation instructions
Remote control
Instructions of use of the motor with the remote control.
The Dooya motor, with integrated radio receiver (433MHz) must be programmed with the
DC90 transmitter. Range of this transmitter: Open 200m, two walls 30m
Up
Stop
Down
P2
●
Mounting the remote control's wall mount base:
Locate a suitable place indoors and drill two holes for
attaching the base (23). Use a cable detector prior to drilling to prevent damaging electric cables or water
pipes.
Insert the two small dowels into the drill holes. Insert the two screws into the dowels and mount the base to
the wall.
Function
Press button
Stop
Up
Down
Retract / close the awing
stop opening/closing process
extract / open the awning
An indicator light (24) is flashing when one of the buttons is pressed. When power off, you
can use hand crank to open or close the awning.
Awning users are not allowed to operate the product more than 2 rounds, in that case,
motor overheat protection status will be automatically started. In that case, pressing on the
remote control cannot run the awning. Users need to wait for about half an hour for any
manipulation.
Pressing “stop” button on remote control when the awning completely opened or closed.
P2
P2
LED light
Switch
Turn on or turn off the LED light
Neutre
Phase
Connection at
the motor
Motor
Power source
8
8
Anschluß
ACHTUNG, Gefahr eines Stromschlags!
Der Stromanschluß der Markise soll nur durch einen
qualifizierten Techniker ausgeführt werden. Einbau gemäß der gültigen Bestimmungen.
• Vergewissern Sie sich, dass die Stromversorgung den Spezifikationen des Geräts (Technische
Daten) entspricht. Unterbrechen der Stromversorgung. Schließen Sie die Kabel im Terminal an,
wie folgt:
Anschluss des Motors
an die Phase
Blau
Braun
Gelb/Grün
N = Neutral
L = Phase
PE
Stromquelle
Farbe des Kabels
Gelb/Grün
Blau
Braun
Markise
Von
An
Erde
Neutral
Live
Connection
CAUTION, risk of electric shock.
The power connection of the awning shall
be performed by a qualified technician only. To be installed under effective
regulation.
Make sure that the power supply corresponds to the appliance's specifications (
Technical
data
). Interrupt power supply. Connect the cables in the terminal as follows.
Colour of cable
Yellow/green
Blue
Brown
From
To
Awning
Earth
Neutral
Live
Operation instructions
Remote control
Instructions of use of the motor with the remote control.
The Dooya motor, with integrated radio receiver (433MHz) must be programmed with the
DC90 transmitter. Range of this transmitter: Open 200m, two walls 30m
●
Mounting the remote control's wall mount base:
Locate a suitable place indoors and drill two holes for
attaching the base (23). Use a cable detector prior to drilling to prevent damaging electric cables or water
pipes.
Insert the two small dowels into the drill holes. Insert the two screws into the dowels and mount the base to
the wall.
Function
Press button
Stop
Up
Down
Retract / close the awing
stop opening/closing process
extract / open the awning
An indicator light (24) is flashing when one of the buttons is pressed. When power off, you
can use hand crank to open or close the awning.
Awning users are not allowed to operate the product more than 2 rounds, in that case,
motor overheat protection status will be automatically started. In that case, pressing on the
emote control cannot run the awning. Users need to wait for about half an hour for any
manipulation.
Pressing “stop” button on remote control when the awning completely opened or closed.
Switch
Turn on or turn off the LED light
Neutre
Phase
Connection at
the motor
Motor
Power source
88
Markisenanwendern ist es nicht erlaubt, das Produkt mehr als zwei Runden lang zu bedienen,
andernfalls schaltet sich die Überhitzungsschutzfunktion automatisch ein. In diesem Fall kann
drücken auf der Fernbedienung den Betrieb der Markise nicht auslösen. Anwender müssen eine
halbe Stunde warten, bevor sie irgendeine Bearbeitung vornehmen können.
Wenn die Markise vollständig aus- oder eingefahren wird, die Stopp-Taste auf der Fernbedienung
drücken.
Bedienungsanweisungen
Fernbedienung
Hinweise für die Benutzung des Motors mit der Fernbedienung.
Der Dooya-Motor mit integriertem Radioempfänger (433 MHz) muss mit dem DC90-Transmitter
programmiert werden. Sendebereich des Transmitters: Offen 200m, zwei Wände 30m
● Anbringen der Fernbedienung mit Wandbasiseinheit: Wählen Sie den geeigneten Platz im
Rauminneren und bohren Sie zwei Löcher, um die Basis anzubringen (23). Verwenden Sie vor
dem Bohren einen Kabeldetektor, um die Schädigung von elektrischen Kabeln oder Wasserrohren
zu vermeiden.
Fügen Sie die zwei kleinen Dübel in die Bohrlöcher ein. Fügen Sie die zwei Schrauben in die Dü-
bel ein und montieren Sie die Basis an der Wand.
Drücken Sie die Taste
Nach oben
Stopp
Nach unten
Schalter
Funktion
Einrollen / Einfahren der Markise
Stopp Ausfahren-/Einfahren-Vorgang
Ausrollen / Ausfahren der Markise
Ein- und Ausschalten der LED-Lampe