10-34
SK714-5 SK815-5 SK815-5 turbo
OPERATION
•
The oil from the charge pump (2) that rotates with the engine flows through a orifice (3) that is installed in the main
piston pump. And the oil always flows to pump charge circuit.
•
Charge pump (2) is fixed capacity pump, so that discharge flow is proportionate to engine rotation speed. With the
oil from the charge pump (2) passed through the orifice, differential pressure is generated at port
A
and port
B
. This
differential pressure actuates the differential pressure sensing valve (
1G
) and makes hydraulic force
F
.
•
By the hydraulic force
F
, the differential pressure sensing valve (
1G
) is moved
direction.
That makes a change of spring (
1D
) load.
In port
C
, the AS valve output pressure that is balanced with spring (
1C
) and (
1D
) load is generated by reducing from
charge pressure of port
G
.
So the AS valve outputs pressure correspond with charge flow that is changed by engine (5) revolution.
RKS00180
3
2
1
C
1
D
1
G
B
D
E
C
G
F
E
5
A
STRUCTURE AND FUNCTION
HYDRAULIC PUMP
Содержание SK714-5
Страница 1: ...WEBM005500 ...
Страница 2: ......
Страница 3: ...SK714 5 SK815 5 SK815 5 turbo WEBM005500 00 1 ...
Страница 18: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 38: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 83: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 108: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 112: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 118: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 126: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 172: ......
Страница 174: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 236: ...40 2 SK714 5 SK815 SK815 5 turbo5 P T O RKS01091 195 Nm 80 Nm 80 Nm STANDARD MAINTENANCE P T O ...
Страница 253: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 256: ......
Страница 257: ......
Страница 258: ...2003 ...