30-40
SK714-5 SK815-5 SK815-5 turbo
INSTALLATION OF THE HYDRAULIC PUMP
•
To install, reverse removal procedure.
Flange screws: 80 Nm
Flange screws: Loctite 262
Pump shaft: Lithium EP MS2 NLGI 2
Pump screws: 195 Nm
Pump screws: Loctite 262
1 - Fill the tank up to maximum level.
Hydraulic oil: max. 39
Bleed the air from the pump.
(For details, see «20. TESTING AND ADJUST-
MENTS»).
2 - Start the engine to circulate the oil and check that there
are no leaks.
3 - Stop the engine, check the levels and, if necessary, top
them up.
4 - Bleed the air from the hydraulic circuits and pressurise
the tank.
(For details, see «20. TESTING AND ADJUST-
MENTS»).