14.3
Guide for electrical installation
—
Check that the drive and motor match each other. Compare the rated voltage and
rated current of the unit.
—
Ensure that there is proper earthing of the drive and the motor. Use correct earthing
and EMC-shielding according to the AKD installation manual. Earth the mounting
plate and motor housing.
—
The shielding must be connected at both ends (also refer to the AKD installation ma-
nual).
—
Connect up all system shielding via a wide surface-area contact (low impedance)
and metallized connector housings or EMC-cable glands.
System with AKMH and AKD-N
System with AKMH and AKD-P
English - 50
Servomotors AKMH
Electrical Installation
08/2013
Kollmorgen
ENGLISH
Schaltschrank/
Switchgear cabinet