AKD PDMM User Guide | 24.7 BODE.MODE
BODE.INJECTPOINT Description
0
None
1
Current
2
Velocity
Example
Set BODE.INJECTPOINT to current:
-->BODE.INJECTPOINT 1
Get BODE.INJECTPOINT (already set to current):
-->BODE.INJECTPOINT 1
Related Topics
1.2.1.5 Bode (set command source)
1 Settings (set command source)
Error: Invalid Bode plot mode for this function. (pg 154) and others)
24.7 BODE.MODE
General Information
Type
R/W Parameter
Description
Sets the mode of the excitation.
Units
N/A
Range
0 to 4
Default
Value
0
Data Type
Integer
See Also
BODE.INJECTPOINT (pg 226)BODE.VAMP (pg
232)
Start Version M_01-00-00-000
Description
BODE.MODE sets the mode of the excitation. The excitation can be set to the modes shown in
the table below. BODE.MODE is always set to
None
when Ethernet communication is dis-
connected. The peak amplitude of the excitation is set by either BODE.IAMP or BODE.VAMP
(depending on BODE.INJECTPOINT).
BODE.MODE is subject to a watchdog timer (BODE.MODETIMER) as follows:
l
If BODE.MODETIMER is 0, then BODE.MODE is not affected.
l
If BODE.MODETIMER is set to a value greater than 0, then BODE.MODE will be set to
0 (None) after the BODE.MODETIMER time milliseconds.
l
If BODE.MODE is a nonzero value, and you reset BODE.MODE to another nonzero
value, you will reset the watchdog timer. This mechanism is intended to turn off the exci-
tation signal if you lose communication with the drive.
227
Kollmorgen™ | December 2012
Содержание AKD PDMM series
Страница 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Страница 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Страница 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Страница 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Страница 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Страница 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Страница 246: ...AKD PDMM User Guide 26 6 DIN1 INV to DIN7 INV Digital Inputs and Outputs 246 Kollmorgen December 2012...
Страница 340: ...AKD PDMM User Guide 33 11 FBUS TYPE 2 EtherCAT 3 CANopen 4 EthernetIP 5 Profinet 340 Kollmorgen December 2012...
Страница 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Страница 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Страница 513: ...This page intentionally left blank 513 Kollmorgen December 2012...